SCS Unit Hydrograph
StormShed3G uses two forms of the Unit Hydrograph. When the peaking factor is set to the
default value of 484, it uses the following table:
| SCS Dimensionless Unit Hydrograph |
| 0.0000 | 0.0300 | 0.1000 | 0.1900 | 0.3100 |
| 0.4700 | 0.6600 | 0.8200 | 0.9300 | 0.9900 |
| 1.0000 | 0.9900 | 0.9300 | 0.8600 | 0.7800 |
| 0.6800 | 0.5600 | 0.4600 | 0.3900 | 0.3300 |
| 0.2800 | 0.2070 | 0.1470 | 0.1070 | 0.0770 |
| 0.0550 | 0.0400 | 0.0290 | 0.0210 | 0.0150 |
| 0.0110 | 0.0050 | 0.0000 | | |
For user defined peaking factors, StormShed3G uses an equation
for the unit hydrograph.
Delmarva Unit Hydrograph
The Delmarva Dimensionless Unit Hydrograph is available only with a peaking factor of 484.
| Delmarva Dimensionless Unit Hydrograph |
| 0.00000 | 0.11100 | 0.35600 | 0.65500 | 0.89600 |
| 1.00000 | 0.92900 | 0.82800 | 0.73700 | 0.65600 |
| 0.58400 | 0.52100 | 0.46500 | 0.41500 | 0.37100 |
| 0.33100 | 0.29600 | 0.26500 | 0.23700 | 0.21200 |
| 0.19000 | 0.17000 | 0.15300 | 0.13800 | 0.12300 |
| 0.10900 | 0.09700 | 0.08600 | 0.07600 | 0.06600 |
| 0.05700 | 0.04900 | 0.04100 | 0.03300 | 0.02700 |
| 0.02400 | 0.02100 | 0.01800 | 0.01500 | 0.01300 |
| 0.01200 | 0.01100 | 0.00900 | 0.00800 | 0.00800 |
| 0.00600 | 0.00600 | 0.00500 | 0.00500 | 0.00000 |